Michael-Gossman-Medical-Physicist-Expert.jpg

8/6/2013· Medical - Medicine

Intact Performance of a Cochlear Implant Following Radiotherapy in a Child With Acute LymphobLastic Leukemia

By: Michael Gossman

Cochlear implants, via direct electrical stimulation of the auditory nerve, allow the restoration of hearing and speech recognition in both adults and children having sensorineural deafness. These devices typically contain both extemal components (speech processor, microphone, transmitter) and intemal components (including the cochlear stimulator and electrode array), which are surgically placed under the skin behind the ear and in the cochlea.

Michael-Gossman-Medical-Physicist-Expert.jpg

6/28/2013· Medical - Medicine

Evaluation of a Ventricular Assist Device: Stability Under X-Rays and Therapeutic Beam Attenuation

By: Michael Gossman

Improved outcomes and quality of life of heart failure patients have been reported with the use of left ventricular assist devices (LVADs).

Michael-Gossman-Medical-Physicist-Expert.jpg

7/18/2013· Radiology

Evaluation of a Ventricular Assist Device: Stability in a Proton Beam Therapy

By: Michael Gossman

Inadequate research exists regarding testing of a ventricular assist device (VAD) for susceptibility to radiation damage. Specifically, minimal data are available to radiation oncologists prescribing treatment plans for patients with an implanted VAD. As the number of implanted devices increases, patients requiring radiation at tissue sites near or at the device will increase.

Michael-Gossman-Medical-Physicist-Expert.jpg

1/8/2013· Radiology

Planning Dosimetry Near Vascular Ports

By: Michael Gossman

New research shows the effects of electron beams on implanted vascular access ports composed of plastic, determining how they impair the fluence of radiation around them.

Michael-Gossman-Medical-Physicist-Expert.jpg

10/23/2012· Radiology

Effects on Radiation Oncology Treatments Involving Various Neuromodulation Devices

By: Michael Gossman

Abstract. Object: Where no society-based or manufacturer guidance on radiation limits to neuromodulation devices is available, this research provides the groundwork for neurosurgeons and radiation oncologists who rely on the computerized treatment plan clinically for cancer patients.

Michael-Gossman-Medical-Physicist-Expert.jpg

7/25/2012· Medical Physics

Beam Profile Disturbances From Implantable Pacemakers or Implantable Cardioverter-Defibrillator Interactions

By: Michael Gossman, MS, DABR, RSO

Abstract-The medical community is advocating for progressive improvement in the design of implantable cardioverter-defibrillators and implantable pacemakers to accommodate elevations in dose limitation criteria.

Michael-Gossman-Medical-Physicist-Expert.jpg

5/14/2012· Radiology

Radiation Therapy in Cochlear Implant Recipients

By: Michael Gossman, MS, DABR, RSO

Since the first commercial multichannel cochlear implant was marketed by Cochlear in 1985 (1), use of the device has grown exponentially. As of mid-2010, more than 188,000 people worldwide have received a cochlear implant system (2). Recent developments in the manufacturing of cochlear implants by the market leader, Cochlear Limited (based in Australia), have resulted in an aim to provide electronically stable models (3).

Michael-Gossman-Medical-Physicist-Expert.jpg

3/13/2012· Medical Physics

Providing Solid Angle Formalism for Skyshine Calculation

By: Michael Gossman, MS, DABR, RSO, et al

We detail, derive and correct the technical use of the solid angle variable identified in formal guidance that relates skyshine calculations to dose-equivalent rate.

Michael-Gossman-Medical-Physicist-Expert.jpg

1/2/2010· Medical Physics

Establishing Radiation Therapy Treatment Planning Effects Involving Implantable Pacemakers And Implantable Cardioverter-Defibrillators

By: Michael Gossman, MS, DABR, RSO, et al

Recent improvements to the functionality and stability of implantable pacemakers and cardioverter-defibrillators involve changes that include efficient battery power consumption and radiation hardened electrical circuits. Manufacturers have also pursued MRI-compatibility for these devices

Michael-Gossman-Medical-Physicist-Expert.jpg

1/3/2010· Medical Physics

NRC Restrictions On The Packaging Of Radioactive Material Should Be Expressed More Explicitly Than Simply in terms of "Activity"

By: Michael Gossman, MS, DABR, RSO, et al

As promulgated by the Nuclear Regulatory Commission, packaging regulations for radioactive material are confusing (e.g., “activity” vs “contained” activity vs “total” activity). As a consequence, medical physicists are forced to secondguess the intent of the regulations.

Featured profiles

Sanjay
Sanjay Adhia, MD

Forensic Psychiatrist and Med-Legal Consultant

Sanjay G. Adhia, M.D., Forensic Psychiatry, Professional Association

Stefan
Stefan Boedeker

Director

BRG

David G.
David G. Shreve, PE

Senior Consultant

Ivey Engineering, Inc.

Experts.com-No broker Movie Ad

Follow us

linkedin logo youtube logo rss feed logo
;